NSHTÖU

As connection and control cable in lifting devices, hoisting plants and transporting machines for heavy mechanical load, and as drum and drag cable or hawser in dry, damp or wet rooms and in wet industrial conditions. The cable can be reeled and is resistant to acids, lyes, and oils.

Share:

SKU: EMP11035 Category:

Description

For fixed installation in buildings, in free air, in ground for direct burial and in water as it is the flame retardant according to IEC60332-1. Cable includes UV protection.

Additional information

Conductor material

Tinned copper

Conductor construction

Fine stranded, class 5

Insulation

halogen-free, Rubber (EPR) 3GI3

Inner sheath

Rubber GM1b

Torsion protecting element

Polyester braid

Sheathing material

Color of outer sheath

Flame retardant

VDE 0482-332-1-2/IEC 60332-1

Maximum temperature at conductor

90 °C

Maximum operating temperature, fixed

Temperature, moved/during installation

-20 / +80 °C

Torsion

+/- 25 °/m

Nominal voltage Uo

600 V

Nominal voltage U

1 kV

Test voltage

3 kV

Core identification

Colours acc. VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers

Additional information

The maximum permissable speed is v=2 m/s.