RG-11/U-4 Cu/Cu-HFFR

It is used as a connection cable at indoor catvcctv systems and satellite systems for which low attenuation is demanded. These cables with flame retardant characteristics due to their structures are used at crowded places (shopping malls, hotels etc.), where human health must not be endangered by smoke and corrosive gases resulting from fires.

Share:

SKU: EMP11107 Category:

Description

For fixed installation in buildings, in free air, in ground for direct burial and in water as it is the flame retardant according to IEC60332-1. Cable includes UV protection.

Additional information

Conductor

1.63 mm Ø electrolitic solid copper

Insulation

7.20 Ø physical foam PE

1. Screen

AL-pase tape shielded (100 % coverage)

2. Screen

Tinned copper braid (60 % coverage)

Sheath

10,30 Ø HFFR compound black or gray

Insulation resistance (max)

>2000 M km

Radni kapacitet (MAX)

53 pF/m

Velocity of propagation

82%

Operating voltage

2.0 kV

Test voltage

5.0 kV

Bending radius

20 x D mm

Temperature range

-40°C / +70ºC

Impedance

75±3 Ω

Flame test

IEC 60332-1-2/VDE 0482-332-1-2 EN 60332-1-2

Smoke density

IEC 61034-2/VDE 0482-1034-2 EN 61034-2

Test on corrosiveness of combustion gases

IEC 60754-2/VDE 0482-267-3 EN 50267-2-3