PP-J / H05VV-F

For medium mechanical stress in household, kitchen and office rooms. For household appliances also in wet rooms. Applicable for cooking and heating devices provided that the cable is not in touch with hot parts or heat irradiation. Not for permanent use in free air.

Share:

SKU: EMP11029 Category:

Description

For fixed installation in buildings, in free air, in ground for direct burial and in water as it is the flame retardant according to IEC60332-1. Cable includes UV protection.

Additional information

Conductor material

Bare copper

Conductor construction

Fine stranded, class 5

Insulation

PVC YI2

Sheathing material

Flame retardant

VDE 0482-332-1-2/IEC 60332-1

Maximum temperature at conductor

60 °C

Maximum operating temperature, fixed

Bending radius, fixed installation

3 x DA

Bending radius, moved application

5 x DA

Nominal voltage Uo

300 V

Nominal voltage U

300 V

Test voltage

2 kV

Core identification

Colors acc. VDE 0293 (HD308)