LiYCY

Application: 

For signal transmission between electronic devices, in computer systems or process control units with increased requirements to electromagnetic compatibility.

 
Conductor material:  Bare copper 
Conductor construction:  Fine stranded, class 5
Insulation: PVC
Screen: Cu-braiding
Screen over strand: Cu-braid, tinned
Screen coverage: 70%
Sheathing material: PVC
Flame retardant: VDE 0482-332-1-2/IEC 60332-1                        
Oil resistant: EN 60811-2-1
Maximum operating temperature, fixed: -30 / +80 °C
Temperature, moved/during installation: -5 / +70 °C
Operating capacity: 120 nF/km
Nominal voltage Uo: 250 V
Nominal voltage U: 250 V
Test voltage: 1,2 kV
Core identification: Colours acc. DIN 47100